1. Windows installation
Installing and Accessing the ZIP Version of MONICA on Windows
Starting with version 3.6.x, MONICA is distributed as a ZIP archive instead of a traditional installer.
This makes setup simpler and more flexible where users can keep multiple MONICA versions on their computer and easily run a specific one for each project.
1. Extracting MONICA
-
Download the latest Windows ZIP package from the MONICA Releases Page, for example:
monica_win64_3.6.32.toth_ser_TUA.zip -
Extract the contents to a convenient location, such as:
C:\monica\ -
After extraction, the folder structure should look like this:
There is no installation process. Simply unzipping the archive is enough to make MONICA ready for use. User may also maintain several versions in parallel (e.g., C:\monica_3.6.12\, C:\monica_3.7.0).C:\monica ├── bin ├── documentation ├── monica-parameters └── projects
2. Running MONICA
Because the ZIP version isn’t registered automatically in Windows, user can either:
-
Run the included example project, or
-
Add MONICA to the user system PATH to use it from anywhere.
Option 1: Run the Example Project (Recommended)
MONICA comes with a ready-to-run example project.
-
Open Command Prompt (Win + R → type
cmd→ press Enter). -
Navigate to the example folder:
cd C:\monica\projects\Hohenfinow2-single-run -
Run the simulation by typing:
run_monica.cmd
The script automatically:
- Points to the MONICA executable in the
binfolder - Sets required environment variables (e.g.,
MONICA_PARAMETERS) - Runs a predefined example simulation
When the run is complete, a file named sim-out.csv will appear in the same folder.
Open it in Excel or any text editor to view the results.
Option 2: Run MONICA Manually (Advanced)
If user prefer to run MONICA from anywhere on the system
i. Add the path to bin folder (e.g. C:\monica\bin) to the PATH environment variable
ii. Create a new environment variable named MONICA_PARAMETERS and set its value to: C:\monica\monica-parameters
- Open a new Command Prompt and verify the installation:
monica-run.exe - -help
3. Updating an Existing Installation
-
If the user already has an older MONICA installation (for example under%USERPROFILE%\AppData\MONICA), user can simply replace the files in the existing bin folder with those from the new ZIP.
-
However, it is generally recommended to use the ZIP-based workflow exclusively. This avoids version conflicts and allows each project to reference its own MONICA version explicitly.
-
The ZIP-based approach will now be the default method for running MONICA.
4. Verifying the Installation
-
To confirm that MONICA runs correctly:
-
Navigate to the example folder:
C:\monica\projects\Hohenfinow2-single-run -
Run the simulation by typing:
run_monica.cmd
If the setup is correct, the model will complete a short test simulation and generate an output file named sim-out.csv in the same directory. This confirms that MONICA is successfully installed and functional.